NTI INSTALLATION MANUALS
Part 9 - Controls
Approximate Time / Temperature Relationships in Scalds
WARNING
120 o F
More than 5 minutes
An ASSE 1017 or ASSE 1070 temperature limiting or mixing valve is recommended in installations servicing disabled or elderly persons, or children. Mixing valves do not eliminate the risk of scalding. To avoid scalding: • Set the water heater set point temperature as low as possible. • Feel water before bathing or showering. • If thermostatic valves are required, use devices speci cally designed for such purpose. Install these devices in accordance with instructions provided by the manufacturer. Failure to install a temperature limiting or mixing valve and follow these instructions could result in property damage, severe personal injury, or death due to scalds.
125 o F
1 1/2 to 2 minutes
130 o F
About 30 seconds
135 o F
About 10 seconds
140 o F
Less than 5 seconds
145 o F
Less than 3 seconds
150 o F
About 1 1/2 seconds
155 o F
About 1 second
Table 26 - Time and Temperature Relationship in Scalds
E. User Menu
Activate change by pressing the OK button. + / - buttons scroll through and change values. Press OK button to con rm a change. Press ESC to return without change. 1. I-NET WIFI ON/OFF Wi-Fi AP Access point open for 10 minutes SN Shows Wi-Fi (Not Appliance) serial number RESET Delete Wi-Fi settings and Disconnect user account ITIME ON/OFF - Date and time set via the Internet. ITEMP Use Internet weather (only without outdoor sensor) 2. Date and Time (Only visible when ITIME is set to OFF) The following values are displayed in a sequence. Day (1-31) Month (1-12) Year (year) Time (hh: mm) (*) 3. DHW Comfort Function (Only applicable with Combi models) OFF DHW Comfort function deactivated ON DHW Comfort function Active 4. Automatic C.H. temperature control / AUTO function OFF AUTO function deactivated ON AUTO function Active (AUTO appears on the display) 5. Room temperature Day / only applicable if using NTI room sensor(s) 6. Room temperature Night / only applicable if using NTI room sensor(s) 7. Time programs – heating schedule / only applicable if using NTI room sensor(s) 0+24 h Always active
Press the MENU button to open the user menu. To navigate within the menu or parameters, press the + and - buttons ( or ). To change a parameter, select it by pressing the OK button. To change the set value, press the + and - buttons ( or ). Press the OK button to save. To exit without saving the changes, press the ESC button.
Figure 80 - Access user menu
For parameters 4 to 11 in Table 27, it is also possible to adjust the same parameters for Zones 2 and 3, if applicable. NOTE: Zone 3 is only applicable when using an optional NTI zone controller. By pressing the HISTORY button after accessing the parameter, the number 1 or 2 of the selected zone appears next to the
P1
Family program
heating symbol: . Continue to change the setting as described above. /
P2
Program no lunch
P3
Program with lunch
06-22 h
C.H. active from 06:00 to 22:00
P EXT
Time program de ned by REMOCON room unit or NTI NET app.
8.
Outdoor Reset Curve Slope (only with AUTO function active) /
9.
Outdoor Reset Curve Parallel Shift (only with AUTO function active) / Setting range + -7 at low temperature and + -14 at high temperature range (each step + or - 1.8°C)
10.
Automatic summer / winter changeover
/
ON
Active
OFF
Function deactivated
11.
Summer / winter changeover temperature
/
Table 27 - User menu
64
Made with FlippingBook - Online magazine maker