NTI SUBMITTALS
TRIN & STOR “ V ” SERIES SUBMITTAL Section 1 – General Specifications Section 2 – Product Dimensions
THE FUTURE OF HOME HEATING
Project Name: _______________________________________________ Date: _______________________________ Location: _______________________________________________________________________________________ Engineer: _______________________________________________________________________________________ Contractor: __________________________________________________ Rep: _______________________________
1 – GENERAL SPECIFICATIONS
Product Features:
Factory Supplied Items
Relief Valve, T&P, 3/4”, 150 psi Tank Sensor
Tank is constructed out of Type 444 Stainless Steel Coil is constructed out of Type 316L Stainless Steel Tanks are 100% pickled and passivated (inside and outside) to regenerate the chromium oxide layer, an extremely important process for corrosion resistance Fittings are constructed out of Type 316L stainless steel Maximum operating pressure 150 psi Insulated with 2 inch thick Expanded Polyurethane Foam (R value > 9) Painted metallic outer shell with high quality look and feel 3/4 ” female NPT temperature and pressure relief valve connection Stainless steel well for insertion of Tank Sensor or Aquastat 1- 1/2” cleanout/inspection ports on top and side Recirculation connection
Tank Sensor Features
Incorporates a 10K thermistor and a UL353 rated normally closed safety switch Connects directly to any NTI gas-fired boiler Allows the tank temperature to be controlled from the boiler
Indirect Water Heater Specifications
Coil Flow Rate (GPM)
Hour 1 Recovery 2 (USG @ Outlet Temp)
Continuous Rate 2 (GPH & Outlet Temp)
Storage Capacity (USG)
Boiler Output (MBH)
Coil Drop (Feet)
Weight (lbs)
Model
Type
Empty Filled 1
140º F
115º F
140º F
115º F
V40
38
95
428
216
319
160
10
1.6
182
287
V50
51
117
556
251
373
180
10
2.0
211
333
Stainless Steel Indirect
V65
64
134
690
334
485
240
15
3.8
277
433
V80
77
165
835
384
558
300
15
5.1
314
492
V120
116
232
1235
489
717
350
20
10.0
390
616
Notes: 1 Ensure the location chosen for installation can support the weight of the tank when filled with water. 2 Ratings based on 50ºF inlet water temperature and 200ºF boiler water outlet temperature.
Recommended Service Clearances [in]
Restrictions
Top
12
MAWP
150 psi
Connection Side
12
Max Tank Temp
190º F
Boiler Connections
As required
Max Boiler Temp
210º F
NTI Boilers Inc. NTI Boilers Inc. 30 Stonegate Drive, Saint John, NB E2H 0A4 Canada Technical Service: 1-800-688-2575 Fax: 1-506-432-1135 Web: http:// www.ntiboilers.com NTI Boilers Inc. reserves the right to change these specifications without notice 2022-07-12 | Rev.0
Made with FlippingBook - Online Brochure Maker